Research Article
Fault Tolerant Control for Civil Structures Based on LMI Approach
Table 2
Suppressing effect comparisons among the bared structure, TMD structure, AMD structure without faults, and AMD H∞ structure with faults.
| Systems | cm | cm | cm | cm | kN |
| Bare system | 4.04 | 2.81 | 1.68 | — | — | TMD system | 2.69 | 2.22 | 1.57 | 25.08 | — | AMD system without faults using | 1.88 | 1.08 | 0.86 | 78.38 | 15.46 | AMD system with faults using | 1.90 | 1.37 | 2.30 | 108.7 | 209.1 | AMD system with faults using FTC | 2.06 | 1.35 | 0.71 | 83.36 | 16.00 |
|
|
represents H∞ state feedback control.
|