Research Article
Study of Intelligent Photovoltaic System Fault Diagnostic Scheme Based on Chaotic Signal Synchronization
Table 3
Simulated fault diagnosis results.
| Qty | EDPF1 | EDPF2 | EDPF3 | EDPF4 | EDPF5 | EDPF6 | EDPF7 | EDPF8 | EDPF9 | Results |
| 1 | 1.000 | −0.585 | −0.839 | −0.981 | −0.722 | −0.931 | −0.893 | −0.991 | −1.000 | PF1 | 2 | 1.000 | −0.585 | −0.839 | −0.981 | −0.722 | −0.931 | −0.983 | −0.991 | −1.000 | PF1 | 3 | −0.186 | 1.000 | −0.224 | −0.910 | −0.337 | −0.670 | −0.485 | −0.958 | −1.000 | PF2 | 4 | −0.176 | 1.000 | −0.224 | −0.910 | 0.337 | −0.670 | −0.485 | −0.958 | −1.000 | PF2 | 5 | −1.000 | −0.357 | 1.000 | −0.549 | −0.004 | 0.054 | 0.564 | −0.662 | −0.760 | PF3 | 6 | −1.000 | −0.357 | 1.000 | −0.549 | −0.004 | 0.054 | 0.565 | −0.662 | −0.759 | PF3 | 7 | −1.000 | −0.885 | −0.642 | 1.000 | −0.822 | −0.258 | −0.510 | 0.982 | 0.465 | PF4 | 8 | −1.000 | −0.885 | −0.642 | 1.000 | −0.822 | −0.258 | −0.510 | 0.987 | 0.468 | PF4 | 9 | −0.584 | 0.406 | 0.366 | −0.843 | 1.000 | −0.420 | −0.093 | −0.926 | −1.000 | PF5 | 10 | −0.584 | 0.406 | 0.369 | −0.842 | 1.000 | −0.419 | −0.091 | −0.926 | −1.000 | PF5 | 11 | −1.000 | −0.633 | 0.140 | −0.007 | −0.432 | 1.000 | 0.562 | −0.162 | −0.289 | PF6 | 12 | −1.000 | −0.631 | 0.147 | −0.007 | −0.429 | 1.000 | 0.571 | −0.161 | −0.289 | PF6 | 13 | −1.000 | −0.530 | 0.459 | −0.170 | −0.273 | 0.648 | 1.000 | −0.308 | −0.424 | PF7 | 14 | −1.000 | −0.530 | 0.459 | −0.176 | −0.273 | 0.636 | 1.000 | −0.313 | −0.429 | PF7 | 15 | −1.000 | −0.893 | −0.668 | 0.855 | −0.834 | −0.312 | −0.545 | 1.000 | 0.455 | PF8 | 16 | −1.000 | −0.895 | −0.668 | 0.855 | −0.834 | −0.322 | −0.552 | 1.000 | 0.450 | PF8 | 17 | −1.000 | −0.934 | −0.796 | 0.136 | −0.898 | −0.578 | −0.721 | 0.711 | 1.000 | PF9 | 18 | −1.000 | −0.932 | −0.791 | 0.169 | −0.896 | −0.566 | −0.713 | 0.761 | 1.000 | PF9 |
|
|