Research Article

The Use of a Brain Computer Interface Remote Control to Navigate a Recreational Device

Table 1

Results of the command selections made during the training experiments showing the accuracy, total time, and ITR of each subject.

SubjectCommand selections (correct/total)AccuracyTimeITR
no.LeftRightForwardElevateDive(%)(s)(bits/min)

130/3030/3029/3030/3030/3099.30 198104.98
228/3017/3025/3020/3025/3076.70 62028.40
330/3026/3025/3025/3030/3090.70 157812.31
430/3030/3029/3030/3030/3099.30 67130.98
529/3027/3026/3028/3030/3093.30 28868.86
630/3029/3028/3020/3029/3090.70 52337.16
721/3024/3023/3025/3030/3082.00 42443.04
830/3030/3030/3018/3025/3088.70 52236.67
930/3029/3027/3025/3030/3094.00 25079.73
1030/3025/3030/3025/3029/3092.70 63631.02
1130/3029/3030/3022/3030/3094.00 82424.19
1226/3017/3020/3016/3030/3072.70 96817.74