Research Article
Several Treatments on Nonconforming Element Failed in the Strict Patch Test
Table 4
Results of the tip deflection of a cantilever beam subjected to a pure bending
.
| | 0 | 0.5 | 1 | 2 | 3 | 4 | 4.9 |
| Q4 | 28.0 | 21.0 | 14.1 | 9.7 | 8.3 | 7.2 | 6.2 | Q6 | 100 | 78.0 | 56.1 | 42.5 | 41.5 | 44.2 | 47.4 | QM6 | 100 | 80.9 | 62.7 | 54.4 | 53.6 | 51.2 | 46.8 | AGQ6-I | 100 | 100 | 100 | 100 | 100 | 100 | 100 | AGQ6M-I | 100 | 80.8 | 55.4 | 24.1 | 12.9 | 9.4 | 7.6 | AGQ6M-II | 28.0 | 21.2 | 14.1 | 9.2 | 7.3 | 5.9 | 4.9 | AGQ6M | 100 | 83.8 | 66.5 | 60.1 | 61.4 | 60.3 | 56.0 |
| Exact | 100 | 100 | 100 | 100 | 100 | 100 | 100 |
|
|