Research Article

Development and Validation of an Enhanced Coupled-Field Model for PZT Cantilever Bimorph Energy Harvester

Table 2

Resonant frequency of PCB generators and proof mass displacements.

1P2P3P4P5P6P

Resonant frequency (Hz)166.0129.4105.092.883.075.7
Center displacement of proof mass (μm)291403463496633688