Research Article

A PCA and ELM Based Adaptive Method for Channel Equalization in MFL Inspection

Table 2

PSNR of raw data and corrected data.

Index of flawPSNR of raw dataPSNR of median corrected dataPSNR of baseline estimation equalized dataPSNR of adaptive channel equalized dataflaw size (length width depth, unit mm)

116.839325.699926.005626.718240 × 20 × 1
218.621630.428131.098132.59476 perforation
319.050229.096529.267430.04548 perforation
418.595124.066824.132824.618120 × 40 × 4
517.508625.596825.825426.503440 × 20 × 4
616.898821.744822.913624.068320 × 20 × 2
716.468726.534926.890328.193940 × 20 × 2
817.599326.522826.816227.807720 × 40 × 2