Research Article
Static Eccentricity Fault Recognition in Three-Phase Line Start Permanent Magnet Synchronous Motor Using Finite Element Method
Table 3
Frequencies and amplitudes of harmonic components due to static eccentricity in LSPMSM.
|
Feature | Static eccentricity degree (%) | Frequency (Hz) | 16.6 Amplitude (dB) | 66 Amplitude (dB) | 83 Amplitude (dB) |
| | 25 | −49.56 | −41.20 | −38.61 |
| | 75 125 | −52.41 −58.46 | −44.83 −44.79 | −39.34 −43.49 |
| | 350 | −17.96 | −17.39 | −17.00 |
| | 450 | −71.73 | −64.99 | −64.95 |
|
|