Research Article

Static Eccentricity Fault Recognition in Three-Phase Line Start Permanent Magnet Synchronous Motor Using Finite Element Method

Table 3

Frequencies and amplitudes of harmonic components due to static eccentricity in LSPMSM.

FeatureStatic eccentricity degree (%)
Frequency (Hz)16.6
Amplitude (dB)
66
Amplitude (dB)
83
Amplitude (dB)






25−49.56−41.20−38.61






  

75


125

−52.41


 −58.46

−44.83


 −44.79

−39.34


 −43.49

350−17.96−17.39−17.00

450−71.73−64.99−64.95