Research Article

Modeling, Parameters Identification, and Control of High Pressure Fuel Cell Back-Pressure Valve

Table 1

Parameters value.

ParametersIdentified value
InitialOptimized

(kg·m2)0.02250.00297
(V·s/rad)0.01840.01681
(Nm/rad)7.36533.6221
(Nm·s/rad)0.00134
(Nm·s/rad)
(Nm/rad)0.43870.21249
(Nm)0.38290.5306
(Nm·A−1)0.01840.02505
(Nm)0.25650.37039
(Ω)21.9306
(rad)0.30530.302
20.6820.68