Research Article

Fault Diagnosis for Compensating Capacitors of Jointless Track Circuit Based on Dynamic Time Warping

Table 10

Summary of results of all the experiments.

MethodClassification accuracyClassification stability (average)Computation complexity (for one classification)

Comparison of static voltagesVery low (not able to locate the faults)NA*NA
SVM (without DTW)81.29%NANA
Classical DTW99.88%0.9260O (156 × 156 × 17)
DTW with improved local cost measure100%5.0881O (156 × 156 × 17)
DTW with global constraint99.88%6.5735O (29.26% × 156 × 156 × 17)

“NA” means not applicable.