Research Article
Fault Diagnosis for Compensating Capacitors of Jointless Track Circuit Based on Dynamic Time Warping
Table 10
Summary of results of all the experiments.
| Method | Classification accuracy | Classification stability (average) | Computation complexity (for one classification) |
| Comparison of static voltages | Very low (not able to locate the faults) | NA* | NA | SVM (without DTW) | 81.29% | NA | NA | Classical DTW | 99.88% | 0.9260 | O (156 × 156 × 17) | DTW with improved local cost measure | 100% | 5.0881 | O (156 × 156 × 17) | DTW with global constraint | 99.88% | 6.5735 | O (29.26% × 156 × 156 × 17) |
|
|
“NA” means not applicable.
|