Research Article
Seismic Responses of an Added-Story Frame Structure with Viscous Dampers
Table 4
Added-story structure with viscous dampers.
| Story | Floor displacement (mm) | Story drift (mm) | Interstory displacement angle (rad) | Interlaminar shear (kN) |
| 7 | 24.64 | 1.95 | | 14.3 | 6 | 22.69 | 3.99 | | 41.3 | 5 | 18.70 | 2.26 | | 157.4 | 4 | 16.44 | 3.27 | | 263.7 | 3 | 13.17 | 4.10 | | 333.8 | 2 | 9.07 | 4.73 | | 390.7 | 1 | 4.34 | 4.34 | | 448.9 |
|
|