Research Article

Research on Energy-Saving Design of Overhead Travelling Crane Camber Based on Probability Load Distribution

Table 2

Hanging heavy load spectrum of standard recommended by GB/T 3811[10].

Load status levelsNominal load spectrum coefficient, Load spectrum coefficient

≤ 0.1250.4580.1460.125
0.125 < ≤ 0.2500.6090.1120.250
0.250 < ≤ 0.5000.7880.0690.500
0.500 < ≤ 1.0000.9000.040.9