Research Article
Bivariate Nonlinear Diffusion Degradation Process Modeling via Copula and MCMC
Table 1
Light intensity degradation data of 12 LEDs.
| Unit | Inspection time (hour) | 0 | 50 | 100 | 150 | 200 | 250 |
| PC1 | | | | | | | 1 | 100 | 86.6 | 78.7 | 76.0 | 71.6 | 68.0 | 2 | 100 | 82.1 | 71.4 | 65.4 | 61.7 | 58.0 | 3 | 100 | 82.7 | 70.3 | 64.0 | 61.3 | 59.3 | 4 | 100 | 79.8 | 68.3 | 62.3 | 60.0 | 59.0 | 5 | 100 | 75.1 | 66.7 | 62.8 | 59.0 | 54.0 | 6 | 100 | 83.7 | 74.0 | 67.4 | 63.0 | 61.3 | PC2 | | | | | | | 1 | 100 | 73.0 | 65.0 | 60.7 | 58.3 | 58.0 | 2 | 100 | 86.2 | 67.6 | 62.7 | 60.0 | 59.7 | 3 | 100 | 81.2 | 65.0 | 60.6 | 59.3 | 57.3 | 4 | 100 | 66.8 | 63.3 | 59.3 | 57.3 | 56.5 | 5 | 100 | 66.1 | 64.2 | 59.4 | 58.0 | 55.3 | 6 | 100 | 76.5 | 61.7 | 61.3 | 59.7 | 56.0 |
|
|