Research Article

A PLS-Based Weighted Artificial Neural Network Approach for Alpha Radioactivity Prediction inside Contaminated Pipes

Table 2

Prediction result comparisons of the PLS and BP.

Pipe diameter Pipe lengthDistance to source Radioactive strength Wind speed FluxMeasuring resultsPLSBPNormal BP

431505032000.914.76139.83140.0233155.7231
431507032000.914.76130.27135.4798150.1133
4315013032000.914.76113.1116.2733121.2121
431703032000.94.76156.28158.1347159.1684
481703032000.95.93160.66162.5901164.5812
581703032000.98.65197.72192.5488172.3124
661703032000.911.04195.28186.8596181.8596
781703032000.913.07156.8163.8596164.7347
841703032000.918.05167.74166.8902167.809
58403032000.918.62152.04151.2389150.4819
5817013032000.54.71112.38107.0745104.0712
5817013032000.666.25127.02120.6906118.6332
5817013032000.87.56133.54127.905125.8907
5817013032000.938.82141.4136.5578130.3024
5817013032001.039.77145.98137.33133.115
5817013032001.1510.9146.58138.7476135.7476
5817013032001.2311.74144.32136.7589136.7589
5817013032001.3312.6143.86138.5632138.5632
5817013032001.4213.48142.38136.99140.0615