Illumination level identification results.
| Illumination level | 100% | 95% | 85% | 75% | 70% | 65% | 55% | 45% | 35% | 25% | Number of data | 322 | 322 | 320 | 320 | 318 | 319 | 317 | 316 | 315 | 318 |
| Normal | 100% (322/322) | 100% (322/322) | 99.69% (319/320) | 95.31% (305/320) | 1.26% (4/318) | 0.31% (1/319) | 0% (0/317) | 0.32% (1/316) | 0.63% (2/315) | 0.94% (3/318) | First string shaded | 0% (0/322) | 0% (0/322) | 0% (0/320) | 0% (0/320) | 0% (0/318) | 0% (0/319) | 0% (0/317) | 0% (0/316) | 0% (0/315) | 0% (0/318) | Second string shaded | 0% (0/322) | 0% (0/322) | 0.31% (1/320) | 4.69% (15/320) | 98.74% (314/318) | 99.69% (318/319) | 100% (317/317) | 99.68% (315/316) | 99.36% (313/315) | 99.06% (315/318) | Third string shaded | 0% (0/322) | 0% (0/322) | 0% (0/320) | 0% (0/320) | 0% (0/318) | 0% (0/319) | 0% (0/317) | 0% (0/316) | 0% (0/315) | 0% (0/318) |
|
|