Research Article

A Dynamic Optimization Strategy for the Operation of Large Scale Seawater Reverses Osmosis System

Table 5

Comparison of computing results with different feed temperatures.

(°C)Simulation time (s)Optimization time (s)Total time (s)Iter. (104 CNY)Bias (%)

2179.608129.985209.593433.86547.63
2386.235132.297218.532433.71663.49
25103.328162.453265.781563.59130.00
2797.141120.875218.016393.4915−2.78
29109.032123.031232.063423.4202−4.76