Research Article

Energy Demodulation Algorithm for Flow Velocity Measurement of Oil-Gas-Water Three-Phase Flow

Table 5

The comparison of experimental values and the actual values for oil-gas-water three-phase flow gas velocity and liquid velocity.

Condition Experiment valueThe gas velocity actual valueMeasurement errorExperiment valueThe oil velocity actual valueMeasurement error

10o1g1w80.3780.3682.72%0.3360.3688.69%
10o1g2w70.7430.7370.81%0.3750.3681.90%
10o2g2w60.6980.7375.29%0.7550.7372.44%
15o3g3w91.1241.1051.72%1.0721.1052.98%
15o3g6w62.1942.2110.77%1.1811.1056.88%
15o4g1w100.3870.3685.16%1.3551.4748.07%
15o4g3w81.1521.1054.25%1.5891.4747.80%
20o2g2w160.7680.7374.20%0.7550.7372.44%
20o4g6w102.3042.2114.21%1.5891.4747.80%
20o6g2w120.6680.7379.36%2.3042.2104.25%
20o6g6w82.3042.2104.25%2.1942.2110.77%
20o8g2w100.6880.7376.65%2.8802.9482.31%
30o2g4w241.4401.4742.31%0.7810.7375.97%
30o8g6w162.3042.2114.21%2.7112.9478.01%
30o8g8w142.8802.9472.27%3.0722.9474.24%
30o12g10w83.8403.6844.23%4.6084.4214.23%