Research Article

Improvement of Energy Density in Single Stator Interior Permanent Magnet Using Double Stator Topology

Table 6

Comparative evaluation of various structures of the IPM.

ParametersSSIPMDSIPMDSIPM with thin pole shoeDSIPM with thick pole shoeReference [19, 20]
NumericalMeasurementNumericalNumericalNumericalMeasurementNumerical

[A]6666664
[Ω]3.03.03.03.03.03.06.25
[m3] 4.754.754.754.754.754.754.75
[Nm]0.650.60.640.8521.601.680.8
[Nm/A]0.1080.10.1060.1420.2670.280.2
[Nm/A/m3] 2.282.12.232.985.625.8916.84
[Nm/A/ ] 10.81010.614.226.7280.02
[Nm2A2/W/m3]2.452.12.364.241516.58.42