Simulation performances via affine nonlinear system.

Load proportion  kJ/kg With feed-water flow
(kg/s) (%) (s) (kJ/kg) (s)

100% 486 3.7 8 4
90% 437.4 4.1 9 4
80% 388.8 1.2 11 5
70% 340.2 4.2 9 4
60% 291.6 3.9 8 6
50% 243 4.3 9 6
40% 194.4 3.9 10 7
30% 145.8 4.2 8 5