Numerical comparison between the simulated magnetic flux density and the corresponding measured fields from Figures 7 and 8 after subtracting initial decay time.

Time (μs)51015202530

(measured), kv/m929394.595.59697.5

(simulated), kv/m90.5919293.59495.5

Percentage difference, %1.62.12.6222