Research Article

Data Mining of the Thermal Performance of Cool-Pipes in Massive Concrete via In Situ Monitoring

Algorithm 1

Grid-search -fold CV method.
(1) Create mesh grid of .
(2) for in the searching grid do
(3)      for to do
(4)        make as the testing data set, and as the training data set
(5)        do SVM with parameters of ( ), calculate the accuracy as
(6)      end loop
(7)      obtain the highest , and record it as
(8) end loop
(9) obtain the highest