Research Article
Data Mining of the Thermal Performance of Cool-Pipes in Massive Concrete via In Situ Monitoring
Table 1
Optimal SVM coefficients.
| Material | | Training data set | Testing data set | | | MSE | | | MSE |
| HDPE | 0.1 | 32 | 32 | 0.00915854 | 0.25 | 8 | 0.006821 | 0.01 | 32 | 32 | 0.00917 | 2 | 8 | 0.006481 | 0.001 | 16 | 32 | 0.00916964 | 2 | 8 | 0.006485 | 0.0001 | 32 | 32 | 0.00917025 | 8 | 8 | 0.006485 |
| Iron | 0.1 | 32 | 32 | 0.00616273 | 8 | 0.5 | 0.003472 | 0.01 | 32 | 32 | 0.00585564 | 0.25 | 4 | 0.003306 | 0.001 | 16 | 32 | 0.00586528 | 0.5 | 4 | 0.003299 | 0.0001 | 16 | 32 | 0.00587013 | 0.0625 | 8 | 0.003301 |
| Optimal results: | | | | | | |
| HDPE | | | | | | |
| Iron | | | | | | |
|
|