Research Article

Improving the Output Power Stability of a High Concentration Photovoltaic System with Supercapacitors: A Preliminary Evaluation

Table 3

Minimum voltage and power of the load resistor under a 1° misalignment angle with different supercapacitor capacitances.

[F] min. [%] min. [%]

None39.3815.51
0.584.5371.45
1.089.6780.41
3.092.7486.01
5.093.2386.92
7.094.7789.81

Tested under 27°C ambient temperature, DNI = 623 W/m2.