Voltage, power, and RE at maximum power point of different models for SM-55 at °C.

(W/m2)Experimental data Five-parameter model Seven-parameter model Six-parameter model RE(5-para)RE(7-para)RE(6-para)

1000 0.230 at 0.735 at 0.734 at
0.715 at 0.300 at 0.299 at

900 0.517 at 0.356 at 0.355 at
0.921 at 0.020 at 0.021 at

800 0.789 at 0.009 at 0.009 at
1.107 at 0.320 at 0.320 at

700 1.051 at 0.364 at 0.365 at
1.271 at 0.598 at 0.598 at

6001.299 at 0.707 at 0.708 at
1.419 at 0.859 at 0.860 at

500 1.546 at 1.050 at 1.050 at
1.560 at 1.113 at 1.113 at

400 1.827 at 1.428 at 1.428 at
1.721 at 1.388 at 1.388 at

300 2.219 at 1.917 at 1.917 at
1.976 at 1.757 at 1.756 at

200 2.969 at 2.766 at 2.765 at
2.554 at 2.449 at 2.449 at

100 5.264 at 5.161 at 5.160 at
4.585 at 4.598 at 4.597 at