Research Article
Pull-In Analysis of the Flat Circular CMUT Cell Featuring Sealed Cavity
Table 3
Comparisons of the maximum and average deflections without biased voltage.
| | /nm | /nm | New model | FEM | Relative error | New model | FEM | Relative error |
| 0 | 131.475 | 127.690 | 2.964% | 43.825 | 42.935 | 2.073% | 0.1 | 117.327 | 115.020 | 2.006% | 39.109 | 38.668 | 1.141% | 0.2 | 103.180 | 102.310 | 0.850% | 34.393 | 34.391 | 0.006% | 0.3 | 91.032 | 89.568 | 1.635% | 30.344 | 30.106 | 0.790% | 0.4 | 78.885 | 76.805 | 2.708% | 26.295 | 25.814 | 1.862% | 0.5 | 64.737 | 64.023 | 1.116% | 21.579 | 21.517 | 0.289% | 0.6 | 52.590 | 51.226 | 2.662% | 17.530 | 17.215 | 1.827% | 0.7 | 39.442 | 38.420 | 2.661% | 13.147 | 12.911 | 1.829% | 0.8 | 26.295 | 25.609 | 2.678% | 8.765 | 8.606 | 1.846% | 0.9 | 13.147 | 12.800 | 2.715% | 4.382 | 4.301 | 1.891% | 1 | 0 | 4.2421e − 4 | — | 0 | 0.002 | — |
|
|