Research Article

A Model of Intelligent Fault Diagnosis of Power Equipment Based on CBR

Table 6

Test results of the experimental cases.

NumberTraining dataTest dataCorrectAccuracyEquipment status

157311510493.04%OK
2337571.43%Low energy discharge
3479777.78%High energy discharge
4306466.67%Partial discharge
583171588.24%Low temperature thermal
65311981.82%High temperature thermal

Average79.83%ā€‰