Research Article
Autonomous Coil Alignment System Using Fuzzy Steering Control for Electric Vehicles with Dynamic Wireless Charging
Table 1
Electrical parameters for power line segment and pick-up coil in Maxwell.
| Parameter | Value |
| Operating frequency | 20 kHz | Current fed through power line | 200 A | Power line | | Number of turns | 8 | Inductance | 842 uH | Pick-up coil | | Number of turns | 50 | Inductance | 2.71 mH |
|
|