Research Article

Joint Feature and Model Selection for SVM Fault Diagnosis in Solid Oxide Fuel Cell Systems

Table 5

PAavg when two subsets of easy-to-measure residuals are adopted. The training set included a mixture of error magnitudes. Class number meaning: 0: nonfaulty system; 1: SOFC stack degradation; 2: air leakage; 3: fuel leakage; 4: reformer degradation.

Control str.Residual subsetAverage producer accuracy (PAavg)
Class number
01234

Constant-voltage2, 3, 40.870.680.880.880.49
1, 2, 3, 40.890.890.890.920.85

Constant-current2, 3, 40.970.450.830.890.97
1, 2, 3, 40.850.570.900.860.99