Research Article
Data-Driven Dynamic Modeling for Prediction of Molten Iron Silicon Content Using ELM with Self-Feedback
Table 1
Direct detecting parameters and their instrumentations.
| Variable (unit) | Notation | Instrumentation (notation) |
| Flow rate of cold air (m3/min) | | HH-WLB differential pressure flowmeter (FT) | Flow rate of rich oxygen (m3/h) | | A+K balance flowmeter (FT) | Blast pressure (kPa) | | DPharp EJA high accuracy pressure transmitter (PT) | Furnace top pressure (kPa) | | DPharp EJA high accuracy pressure transmitter (PT) | Blast temperature (°C) | | Hongguang SBW temperature transmitter (TT) | Blast humidity (g/m3) | | Air humidity sensor (HT) |
|
|