Research Article

Image Denoising via Asymptotic Nonlocal Filtering

Table 1

PSNR and MSSIM comparisons of denoising results of -ANLF with different wavelets, MSSIM results are shown in brackets (noise standard is 30).

Test
image
Sym5Sym8Db5Db8Coif5Rbio5.5Bior5.5Standard variance

House30.79 (0.822)30.83 (0.822)30.82 (0.822)30.80 (0.822)30.85 (0.821)30.65 (0.814)30.81 (0.826)0.066 (0.0036)
Lena30.64 (0.827)30.64 (0.827)30.62 (0.827)30.64 (0.826)30.64 (0.827)30.54 (0.821)30.65 (0.830)0.038 (0.0027)
Rice28.59 (0.779)28.57 (0.778)28.54 (0.778)28.59 (0.778)28.55 (0.777)28.53 (0.778)28.57 (0.779)0.024 (0.0007)