Research Article

Experimental and Numerical Study on the Resistance Performance of an Axial Flow Cyclone Separator

Table 5

Pressure drop of axial flow cyclone separator with inlet velocity of 4 m/s.

Number1234567

Ambient pressure (Pa)101325201325251325101325151325201325251325
Ambient temperature (K)300300300350350350350
Pressure drop by CFD (Pa)70.32139.37173.8960.2989.98119.61149.26
Pressure drop by (8) (Pa)X139.72174.4260.2790.02119.76149.50
Relative error (%)X−0.080.31−0.0020.040.130.16

Number891011121314

Ambient pressure (Pa)101325151325201325251325101325151325201325
Ambient temperature (K)400400400400450450450
Pressure drop by CFD (Pa)52.8778.84104.80130.7847.0870.1893.28
Pressure drop by (8) (Pa)52.7478.77104.79130.8246.8870.0193.15
Relative error (%)−0.25−0.09−0.010.03−0.42−0.24−0.14

Number15161718192021

Ambient pressure (Pa)251325101325151325201325251325XX
Ambient temperature (K)450500500500500XX
Pressure drop by CFD (Pa)116.3642.4063.1793.28104.85XX
Pressure drop by (8) (Pa)116.2842.1963.0193.15104.65XX
Relative error (%)−0.07−0.49−0.25−0.14−0.19XX