Research Article
Three-Dimensional Numerical Analysis of Compound Lining in Complex Underground Surge-Shaft Structure
Table 2
Crack width and reinforcement ratio of lining in different conditions.
| Operation condition | Internal water | External water | /mm | /% | /mm | /% |
|
1st layer | 0.0 | 0.16 | 0.0 | 0.16 |
2nd layer | 0.0 | 0.16 | 0.0 | 0.16 |
3rd layer | 0.0 | 0.16 | 0.0 | 0.16 | 4th layer | 0.04 | 0.63 | 0.0 | 0.16 | Number 1 draft tube | 0.07 | 0.91 | 0.0 | 0.16 | Number 2 draft tube | 0.09 | 1.27 | 0.0 | 0.16 | Number 3 draft tube | 0.08 | 1.19 | 0.0 | 0.16 | Tailrace tunnel | 0.10 | 1.34 | 0.01 | 0.34 | Impedance board | 0.15 | 1.85 | 0.03 | 0.51 |
|
|