Research Article
Feasibility Study on Tension Estimation Technique for Hanger Cables Using the FE Model-Based System Identification Method
Table 4
Results of the tension estimation using the FE model-based system identification method (hinges at both sides).
| Cable number | Frequency | 1 | 2 | 3 | 4 | 5 | SRSS (%) | Tension (kN) |
| 29A | Measured (Hz) | 3.20 | 6.42 | 9.60 | 12.63 | 15.32 | 2.73 | 381.96 | Calculated (Hz) | 3.18 | 6.36 | 9.53 | 12.66 | 15.68 | Error (%) | 0.79 | 0.91 | 0.73 | 0.25 | 2.33 |
| 29B | Measured (Hz) | 3.05 | 6.10 | 9.11 | 12.05 | 15.54 | 3.03 | 334.38 | Calculated (Hz) | 3.02 | 6.04 | 9.06 | 12.05 | 14.93 | Error (%) | 1.04 | 0.87 | 0.52 | 0.00 | 2.66 |
| 36A | Measured (Hz) | 9.38 | 15.91 | 23.15 | 34.82 | 49.14 | 8.31 | 363.89 | Calculated (Hz) | 9.12 | 16.77 | 23.90 | 24.28 | 47.00 | Error (%) | 2.82 | 5.40 | 3.27 | 1.53 | 4.35 |
| 36B | Measured (Hz) | 9.20 | 15.46 | 22.90 | 34.78 | 48.28 | 7.96 | 331.92 | Calculated (Hz) | 8.94 | 16.37 | 23.45 | 33.93 | 46.83 | Error (%) | 2.83 | 5.87 | 2.42 | 2.44 | 3.00 |
|
|