Results of the tension estimation using the FE model-based system identification method (hinges at both sides).

Cable numberFrequency12345SRSS
(%)
Tension
(kN)

29AMeasured (Hz)3.206.429.6012.6315.322.73381.96
Calculated (Hz)3.186.369.5312.6615.68
Error (%)0.790.910.730.252.33

29BMeasured (Hz)3.056.109.1112.0515.543.03334.38
Calculated (Hz)3.026.049.0612.0514.93
Error (%)1.040.870.520.002.66

36AMeasured (Hz)9.3815.9123.1534.8249.148.31363.89
Calculated (Hz)9.1216.7723.9024.2847.00
Error (%)2.825.403.271.534.35

36BMeasured (Hz)9.2015.4622.9034.7848.287.96331.92
Calculated (Hz)8.9416.3723.4533.9346.83
Error (%)2.835.872.422.443.00