Research Article
Fuzzy Control for Seismic Protection of Semiactive Base-Isolated Structures Subjected to Near-Fault Earthquakes
Table 4
Fuzzy control rules adopted for sublevel fuzzy control.
| Velocity of isolated floor | Displacement of isolated floor | NL | NM | NS | ZE | PS | PM | PL |
| NL | VL | VL | L | L | M | S | ZE | NM | VL | L | L | M | S | ZE | S | NS | L | L | M | S | ZE | S | M | ZE | L | M | S | ZE | S | M | L | PS | M | S | ZE | S | M | L | L | PM | S | ZE | S | M | L | L | VL | PL | ZE | S | M | L | L | VL | VL |
|
|