Research Article

A Novel Heat Sink Design and Prototyping for LED Desk Lamps

Table 2

The error analysis of type 1 heat sink.

Monitor point123

Experiment result (°C)50.651.149.8

Simulation result (°C)49.5350.6349.16

Error analysis (%)2.111.3