Research Article
Field Application of Cable Tension Estimation Technique Using the h-SI Method
Table 11
Estimation results of identification parameters through various system identification methods.
| Case | final | Methods | SUA (LOA) | μ-GA (GOA) | h-SI (GOA + LOA) |
| F1 | (MN) | 4.892 | 4.887 | 4.892 | (m) | 0.184 | 0.210 | 0.188 | (Nm2) | 1.182e + 05 | 2.005e + 05 | 1.288e + 05 | (MN) | 55.840 | 73.736 | 58.294 | | 0.033 | 0.043 | 0.034 | | 1,473 | 1,130 | 1,411 |
| F2 | (MN) | 4.841 | 4.832 | 4.841 | (m) | 0.208 | 0.224 | 0.208 | (Nm2) | 1.929e + 05 | 2.595e + 05 | 1.929e + 05 | (MN) | 71.357 | 82.757 | 71.357 | | 0.043 | 0.051 | 0.043 | | 1,147 | 988 | 1,147 |
| F3 | (MN) | 4.362 | 4.887 | 4.892 | (m) | 0.212 | 0.210 | 0.188 | (Nm2) | 2.082e + 05 | 2.005e + 05 | 1.288e + 05 | (MN) | 55.840 | 73.736 | 58.294 | | 0.014 | 0.010 | 0.014 | | 757 | 1,087 | 750 |