Research Article

Field Application of Cable Tension Estimation Technique Using the h-SI Method

Table 7

Extracted natural frequencies from measured data and calculated natural frequencies from FE models for cable number 1 (Hz).

Mode numberUpward-boundDownward-bound
TestFEMError (%)TestFEMError (%)

10.470.46−1.710.46
20.940.92−1.870.920.920.48
31.140.94
41.381.38−0.281.381.380.25
51.841.850.421.841.840.25
62.281.87
72.302.310.302.292.29−0.20
82.762.770.192.752.75−0.11
93.233.230.062.80
103.423.213.210.06
113.693.69−0.013.673.67−0.07
124.154.160.243.74
134.564.134.130.04
144.614.620.254.594.590.07
155.085.080.094.68
165.545.540.035.055.050.07
175.705.515.51−0.02
186.006.000.085.61
196.466.46−0.015.985.97−0.15
206.846.446.43−0.10

—: not extracted.