Research Article

Field Application of Cable Tension Estimation Technique Using the h-SI Method

Table 8

Extracted natural frequencies from measured data and calculated natural frequencies from FE models for cable number 44 (Hz).

Mode numberUpward-boundDownward-bound
TestFEMError (%)TestFEMError (%)

10.75 0.76
21.33 1.33
31.50 1.51 0.50 1.51 1.51 0.33
42.26 2.26 0.06 2.27 2.27 0.05
52.66 2.67
63.01 3.02 0.24 3.02 3.02 0.00
73.77 3.77 −0.03 3.78 3.78 −0.12
83.99 4.00
94.52 4.52 −0.02 4.55 4.54 −0.13
105.29 5.28 −0.18 5.31 5.29 −0.38
115.32 5.34
126.03 6.03 −0.05 6.05 6.05 0.02
136.65 6.67
146.79 6.79 −0.03 6.82 6.81 −0.21
157.55 7.54 −0.19 7.58 7.56 −0.27
167.99 8.01
178.31 8.3 −0.09 8.33 8.32 −0.17
189.06 9.05 −0.09 9.09 9.07 −0.25
199.32 9.35
209.81 9.81 −0.03 9.83 9.83 −0.02

—: not extracted.