Research Article

Impact Pseudostatic Load Equivalent Model and the Maximum Internal Force Solution for Underground Structure of Tunnel Lining

Table 14

Comparison of bending moment (M/kN).

Measurement
number
Test point 1Test point 2Test point 3Test point 4

3.0A324.2−149.7119.6−154
B367.2−173.5132.7−173.5
C347.3−161.1113.7−161.1
4A255.2−93.777.6−81.9
B286.3−109.883−109.8
C271.9−102.669.4−102.6
5A717.1−346.8249.9−247.7
B827.3−399.7306−399.7
C782.2−371.2263.1−371.2
6A369.5−121.7122.8−134.7
B395.5−175.8168.6−175.8
C368−156.3108.5−156.3
31A−144.2380.5−189181.9
B−222.2412.9−222.2170.9
C−205.8389.3−205.8148.4
34A−136.6130.7−78.388.5
B−75.1154.4−75.157.5
C−69.9146−69.949.5

Note: A is the experimental result, B is the result of the calculation, and C is the simulation result.