Research Article
Fractional-Derivative Maxwell Kelvin Model for “5+4” Viscoelastic Damping Wall Subjected to Large Deformation
Table 1
Properties of “5+4” viscoelastic damping wall (at 225% strain and 21.2°C).
| Frequency (Hz) | (MPa) | (MPa) | (MPa·s) | (kN/mm) | (kN/mm) | (kN·s/mm) |
| | 2.65 | 0.76 | 0.29 | 2.65 | 0.76 | 1.52 | | 1.79 | 1.05 | 0.59 | 1.79 | 1.05 | 0.70 | | 1.34 | 0.85 | 0.63 | 1.34 | 0.85 | 0.57 | | 1.16 | 0.89 | 0.77 | 1.16 | 0.89 | 0.45 | | 1.00 | 0.91 | 0.91 | 1.00 | 0.91 | 0.40 | | 0.96 | 0.94 | 0.98 | 0.96 | 0.94 | 0.38 |
|
|