Research Article

An Ultra-Low Frequency Two DOFs’ Vibration Isolator Using Positive and Negative Stiffness in Parallel

Table 4

The natural frequency of vibration transmissibility curves in different directions.

DirectionPS frequency (Calculation)PS frequency (Experiment)Error (%)PNSP frequency (Calculation)PNSP frequency (Experiment)Error (%)

2.80 Hz2.79 Hz0.361.15 Hz1.17 Hz1.74
3.30 Hz3.32 Hz0.911.20 Hz1.21 Hz0.83
2.80 Hz2.75 Hz1.791.10 Hz1.14 Hz3.64