Research Article

Application of Blind Source Separation Algorithms and Ambient Vibration Testing to the Health Monitoring of Concrete Dams

Table 1

A comparison of the calculated and identified no-damping natural frequencies (unit: Hz).

Method12345678910

FEM1.052.513.775.566.257.918.3410.9111.9312.53
SSI1.062.503.785.576.247.858.3510.9111.9212.53
SOBI1.062.513.775.576.247.938.3510.9111.9312.54