Test rig basic parameters.
| Number | Name | Parameters |
| 1 | Pump maximum displacement | 7.9 10−6 m3/rad | 2 | Pitch radius | 0.05 m | 3 | Diameter of Pistons | 0.028 m | 4 | Number of pistons | 9 | 5 | Maximum piston stroke | 0.06 m | 6 | Swash plate maximum angle | 0.65 rad | 7 | Arm length between the actuator and the swash plate pivoting point | 0.056 m | 8 | Swash plate actuator stroke | 0.05 m | 9 | Diameter of the orifice at the bottom of the piston chamber | 0.007 m | 10 | Pump maximum rated speed | 230 rad/s | 11 | Maximum pressure | 270 bar | 12 | Rated flow | 1.1 10−3 m3/s |
|
|