Research Article
Passive Control System for Mitigation of Longitudinal Buffeting Responses of a Six-Tower Cable-Stayed Bridge
Table 7
Control effects using three sets of A, B, and C.
| Criteria reduction factor | Set A kN⋅(s/m)0.52) | Set B kN⋅(s/m)0.58) | Set C kN⋅(s/m)0.77) |
| of tower number 1 | −34.25 | −17.49 | −1.76 | of tower number 2 | 56.95 | 55.59 | 49.04 | of tower number 3 | −7.47 | −0.41 | −4.32 | of tower number 1 | 8.44 | 7.59 | 6.61 | of tower number 2 | 46.41 | 37.33 | 27.92 | of tower number 3 | 24.92 | 19.27 | 12.22 | of tower number 1 | 5.80 | 7.43 | 5.55 | of tower number 2 | 18.14 | 16.01 | 10.20 | of tower number 3 | 23.76 | 19.86 | 12.59 | in the middle of girder span between towers number 1 and number 2 | 12.82 | 12.53 | 8.24 | in the middle of girder span between towers number 2 and number 3 | 21.67 | 18.61 | 11.97 | in the middle of girder span between towers number 3 and number 4 | 23.89 | 19.75 | 12.42 |
|
|