Research Article

Calculation and Analysis of Permanent Magnet Eddy Current Loss Fault with Magnet Segmentation

Table 3

Eddy current losses of permanent magnet under 37th harmonic currents at different stages.

Number of permanent magnet segmentsThe ratio of magnetic length and depth of penetrationEddy current losses under the first and 37th harmonic excitation/WEddy current losses under the first harmonic excitation/WEddy current losses under the 37th harmonic excitation/mW

15.40.82330.802420.9
22.70.51870.51523.5
31.80.36070.332528.2