Research Article

Multiresolution Time-Domain Scheme for Terminal Response of Two-Conductor Transmission Lines

Table 3

Relative errors and runtime of different methods. represents the near end voltage and represents the far end voltage (NDZ = 40, ).

Analysis scheme Relative error for Relative error for Runtime (s)

FDTD0.30%0.92%0.0066
-MRTD0.18%0.57%0.0245
-MRTD0.17%0.54%0.0275