Research Article

A Combined Method in Parameters Optimization of Hydrocyclone

Table 5

Variance analysis of factors to pressure drop.

SourceSum of squaresMean square  valueProb >

Model42521.82104252.181028.54<0.0001
A28.85128.856.980.0268
B15210.82115210.823679.26<0.0001
C67.29167.2916.280.0030
AB120.451120.4529.140.0004
AC74.55174.5518.030.0022
BC16.80116.804.060.0746
11.04111.042.670.1367
1950.1111950.11471.70<0.0001
46.81146.8111.320.0083
25.50125.506.170.0348
Residual37.2194.13
Lack of fit17.2044.301.070.4571
Pure error20.0154.00
Cor total42559.0319

Adj -Squared = 0.9982; Pred -Squared = 0.9937; Adeq Precision = 115.668.