Research Article
A Combined Method in Parameters Optimization of Hydrocyclone
Table 9
Variance analysis of factors to FeSi separation efficiency.
| Source | Sum of squares | df | Mean square | value | Prob > |
| Model | 7.45 | 9 | 0.83 | 22.03 | <0.0001 | A | 0.090 | 1 | 0.090 | 2.38 | 0.1537 | B | 1.20 | 1 | 1.20 | 31.88 | 0.0002 | C | 5.12 | 1 | 5.12 | 136.15 | <0.0001 | AB | 0.017 | 1 | 0.017 | 0.45 | 0.5174 | AC | 0.020 | 1 | 0.020 | 0.53 | 0.4817 | BC | 0.016 | 1 | 0.016 | 0.43 | 0.5275 | | 0.033 | 1 | 0.033 | 0.88 | 0.3694 | | 0.12 | 1 | 0.12 | 3.32 | 0.0982 | | 0.83 | 1 | 0.83 | 22.16 | 0.0008 | Residual | 0.38 | 10 | 0.038 | | | Lack of fit | 0.14 | 5 | 0.028 | 0.59 | 0.7135 | Pure error | 0.24 | 5 | 0.047 | | | Cor total | 7.83 | 19 | | | |
|
|
Adj -Squared = 0.9088; Pred -Squared = 0.8161; Adeq Precision = 17.306.
|