Research Article

Integrated Power Flow and Short Circuit Calculation Method for Distribution Network with Inverter Based Distributed Generation

Table 5

Part of bus voltage of distribution network.

Bus voltage/puFault point
f1f2f3

30.87510.96260.9192
60.50720.84990.6798
900.67810.7020
110.01810.57880.7166
140.03710.35240.7305
170.06030.07240.7461
180.060300.7461
280.52530.86730.4173
310.53870.88010
330.54260.88380.0068