Research Article

Research and Application of Fire Forecasting Model for Electric Transmission Lines Incorporating Meteorological Data and Human Activities

Table 3

The results of typical models without the human index in Anhui province.

ā€‰IndexModel 1Model 2Model 3Model 4Model 5

TrainingTraditional accuracy rate0.95390.95570.95440.95940.9594
Weighted accuracy rate0.95390.96580.95760.98910.9891
Traditional accuracy rate of fire level 11110.99950.9995
Traditional accuracy rate of fire level 200.016700.050.05
Traditional accuracy rate of fire level 30000.14290.1429
Traditional accuracy rate of fire level 400.11110.03700.29630.2963

TestTraditional accuracy rate0.98360.98310.98360.97810.9781
Weighted accuracy rate0.98360.98950.98360.98130.9813
Traditional accuracy rate of fire level 110.998610.99400.9940
Traditional accuracy rate of fire level 200000
Traditional accuracy rate of fire level 300000
Traditional accuracy rate of fire level 400.2500.1250.125