Research Article

CFD Simulations to Study Parameters Affecting Gas Explosion Venting in Compressor Compartments

Table 1

Results of grid independence.

Grid numberCell size (m)Grid cellsOverpressure peak (barg)Max. rate of pressure rise (barg/s)Computing time (h)

Number 10.501105920.101610.511
Number 20.305136000.116912.825
Number 30.2114815440.124913.2415