Research Article
CFD Simulations to Study Parameters Affecting Gas Explosion Venting in Compressor Compartments
Table 1
Results of grid independence.
| Grid number | Cell size (m) | Grid cells | Overpressure peak (barg) | Max. rate of pressure rise (barg/s) | Computing time (h) |
| Number 1 | 0.50 | 110592 | 0.1016 | 10.51 | 1 | Number 2 | 0.30 | 513600 | 0.1169 | 12.82 | 5 | Number 3 | 0.21 | 1481544 | 0.1249 | 13.24 | 15 |
|
|